Record ID
|
Customer
|
Synopsis
|
SRX00090
|
AMT
|
In the user %TEMP% directory, record the program name and
command line options used to translate a file from one format to another.
|
SRX00140
|
AMT
|
Add a class to reference all circles on a drawing.
|
SRX00141
|
AMT
|
Revise the installation programs to not register the files and
folders installed under the ProgramData folder.
|
SRX00169
|
AMT
|
Honor the Start in folder specified in the shortcut to ExpertCAD in the start menu.
|
SRX00176
|
AMT
|
Modify the AutoCAD to ExpertCAD translator to automatically
rename blocks to avoid conflicts with ExpertCAD symbol naming conventions.
|
SRX00184
|
AMT
|
Add the ability to preview an ExpertCAD drawing in Windows
Explorer and the File Open dialog.
|
SRX00196
|
AMT
|
Add ExpertCAD View to the program group for ExpertCAD.
|
SRX00206
|
K&S Tool Die & Manufacturing
|
Disable the AutoCAD export menu if there are no entities in the
class to write in order to avoid creating zero length files.
|
SRX00211
|
Thumb Tool & Engineering
|
Importing DWG files from Autodesk Inventor is not working.
|
SRX00212
|
Thumb Tool & Engineering
|
The text formatting code ‘\T’ is not being translated properly
when importing this AutoCAD file.
|
SRX00213
|
Thumb Tool & Engineering
|
Improperly formed crosshatch entity in this AutoCAD files is
causing the translator to crash.
|
SRX00214
|
AMT
|
An incorrect error is being published when trying to open a file
locked by another program or process.
|
SRX00218
|
Thumb Tool & Engineering
|
Icon tracking speed control is not working properly in the user
interface.
|
SRX00219
|
Thumb Tool & Engineering
|
Add an option to append or replace a file extension when writing
files of a different format.
|
SRX00220
|
AMT
|
Add a geometric stack command to return a point at a parametric
position along a geometric entity on the stack.
|
SRX00220
|
AMT
|
Clicking on the Window close button on the About dialog causes
the license information dialog to display instead of closing the About
dialog.
|
SRX00224
|
AMT
|
Add an option to reverse the effect of the mouse wheel.
|
SRX00225
|
AMT
|
Report the swept angle when measuring an arc in ExpertCAD.
|
SRX00226
|
AMT
|
Add the ability to import ExpertCAD 3D files, PDB files and 3D
IGES files into ExpertCAD.
|
SRX00227
|
Federal
|
Toleranced dual dimensioning is not working properly.
|
SRX00230
|
AMT
|
Add the ability to convert multiple files from one format to
another.
|
SRX00231
|
AMT
|
Handling of interrupts within ScriptLink is not being handled
properly when macro(s) are run from a Windows dialog.
|
SRX00233
|
K&S Tool Die & Manufacturing
|
Looping redraw when opening larger dxf/dwg files in ExpertCAD.
|
SRX00235
|
AMT
|
When redrawing the screen, ExpertCAD doesn’t stop redrawing when
you wish to choose a menu. You have to wait for it to complete.
|
SRX00236
|
AMT
|
Interrupts (Esc key) are not being handled correctly in this
instance.
|
SRX00238
|
gromaTec
|
This AutoCAD .dwg file will not read into ExpertCAD.
|
SRX00239
|
AMT
|
Text in the title block of this AutoCAD file is incorrectly
sized when read into ExpertCAD.
|
SRX00243
|
AMT
|
The ‘$’ character in block names for AutoCAD files is causing
problems with translation to ExpertCAD.
|
SRX00241
|
AMT
|
Add an audit capability to the AutoCAD to ExpertCAD translator.
|
SRX00242
|
AMT
|
The dialog for setting up a class of calls to specific symbols
works poorly.
|
SRX00243
|
AMT
|
Include information more information in the error file produced
by the AutoCAD translators to better understand the cause of any failure.
|
SRX00245
|
AMT
|
Converting an ExpertCAD file to IGES can leave behind an
unwanted temporary file.
|
SRX00246
|
AMT
|
The ExpertCAD to IGES translator does not support BS8888 standard
drawings.
|
SRX00247
|
AMT
|
The AutoCAD to ExpertCAD translator is not recording the correct
version of the translator that produced the ExpertCAD file.
|
SRX00250
|
AMT
|
The default plotcap.txt file is not correct with regards to
plotting TrueType fonts.
|
SRX00251
|
AMT
|
An incorrect error is output when trying to open this corrupt
AutoCAD file.
|
SRX00252
|
Manitowoc Cranes
|
Add the ability to disable the scrolling of the icons on the
right hand of the screen.
|
SRX00255
|
AMT
|
The ‘flatten’ command in ExpertCAD can cause some entities that
were hidden to become visible.
|
SRX00256
|
AMT
|
The scale primitive command in ExpertCAD should work in a manner
consistent with the rotate command; use a point on the geometric stack if
there isn’t a current point.
|
SRX00258
|
AMT
|
Clicking the Cancel button on the dialog for Add Text in
ExpertCAD causes the text to be added to the drawing anyways.
|
SRX00259
|
AMT
|
Changing drawing standard in ExpertCAD does not immediately
update the status bar to show which standard is now in effect.
|
SRX00261
|
Thumb Tool & Engineering
|
When reading or writing ExpertCAD files, open the disk file in a
locked state instead of shared access rights.
|
SRX00262
|
Thumb Tool & Engineering
|
Add an option to enable or suppress trailing zeros for
dimensions in ExpertCAD.
|
SRX00263
|
AMT
|
Checking for the existence of a CL data file when
post-processing from ExpertCAM is not correct.
|
SRX00264
|
Thumb Tool & Engineering
|
An AutoCAD tolerance dimension in this DWG file is not being
translated correctly.
|
SRX00265
|
Thumb Tool & Engineering
|
Stray lines are appearing in one of the layouts for this AutoCAD
drawing.
|
SRX00266
|
Thumb Tool & Engineering
|
Stray lines are appearing in one of the layouts for this AutoCAD
drawing.
|
SRX00267
|
Fairbanks Morse
|
A configurable post processor with an event file is generating
scientific notation for output. This numeric format can’t be read by the
CNC.
|
SRX00270
|
Fairbanks Morse
|
This CAM program is producing an illegal offset error.
|
SRX00275
|
AMT
|
Leave behind a log file that tells what happened when post
processing from ExpertCAM.
|
SRX00276
|
AMT
|
The configurable post processing subsystem will crash if
presented with a CL data file that is not in the correct format.
|
SRX00277
|
AMT
|
Do not add a file to the recent files list in ExpertCAM if the
file can’t be read.
|
SRX00278
|
Pall
|
Add the ability to disable the recent files feature in the file
menu for ExpertCAD.
|
SRX00280
|
Thumb Tool & Engineering
|
The AutoCAD to ExpertCAD translator does not determine the
drawing standard properly for this DWG file.
|
SRX00282
|
AMT
|
Revise the way we setup dimension text in ExpertCAD.
|
SRX00283
|
AMT
|
Add missing glyphs to the ExpertCAD native fonts for various
symbols.
|
SRX00285
|
AMT
|
Revise the user interface for entering geometric tolerance notes
in a feature control frame. The current method is out of date and not fully
featured.
|
SRX00286
|
AMT
|
The Help menu for the font editor ExpertFont and icon editor
ExpertIcon still reference the old .pdf help files.
|
SRX00287
|
AMT
|
The flatten command is not working correctly for point lines.
|
SRX00290
|
gromaTec
|
The purge feature for empty layer names is not working properly.
|
SRX00291
|
AMT
|
Allow ExpertCAD View to run if there is an ExpertView license
available.
|
SRX00292
|
Fontaine
|
Allow ExpertCAD to run in a client/server environment.
|
SRX00294
|
AMT
|
Add support for read & write of AutoCAD 2018 files.
|
SRX00295
|
AMT
|
Honor a color change escape sequence when converting AutoCAD
text notes.
|
SRX00296
|
AMT
|
Add support for symbols commonly found in AutoCAD files so they
convert properly when read into ExpertCAD.
|
SRX00299
|
AMT
|
Add a feature or program that will allow for the batch
translation of many files from one format to another.
|
SRX00300
|
AMT
|
Add Replace and Replace All to the Find Text dialog in
ExpertCAD.
|
SRX00301
|
AMT
|
Record in the ExpertCAD file if the file was created as a result
of translating from one file format to another.
|
SRX00302
|
AMT
|
Allow for more than 256 model views to be created in ExpertCAD.
|
SRX00303
|
AMT
|
The Last revised by and Last revised on in the File/Properties
dialog in ExpertCAD should be read-only.
|
SRX00304
|
AMT
|
Record the drawing properties in the ExpertCAD binary file when
it is first created or subsequently written to disk.
|
SRX00305
|
AMT
|
The IGES to ExpertCAD translator can output a 1 point line that
is not a point line style.
|
SRX00306
|
AMT
|
A polyline entity in this AutoCAD DWG file is not translating
properly to ExpertCAD.
|
SRX00308
|
Bernal
|
Add a Preview capability to Windows Explorer for ExpertCAD
files.
|
SRX00309
|
Bernal
|
Add a Preview capability for the File Open dialog in ExpertCAD.
|
SRX00310
|
ITW Drawform
|
Add the ability to set the size of text in ExpertCAM.
|
SRX00311
|
AMT
|
Prevent the output of -0 (or -0.0) when formatting floating
point numbers for output in the message area and display in dialogs.
|
SRX00314
|
AMT
|
The scale command doesn’t handle the case of a malformed current
line properly.
|
SRX00315
|
AMT
|
Change the drawing order of entities in ExpertCAD so that
selected entities always draw last.
|
SRX00316
|
AMT
|
Implement datum target notes in ExpertCAD that comply with
current drawing standards.
|
SRX00318
|
AMT
|
Add support for creating datum feature symbol notes in
ExpertCAD.
|
SRX00319
|
AMT
|
Revise the geometric tolerance feature control frame icon to
make it easier to use and more complete.
|
SRX00321
|
K&S Tool Die & Manufacturing
|
ExpertCAD does not recognize this IGES file as being a valid
IGES file.
|
SRX00322
|
Daman Products
|
When checking for the presence of the default printer in
ExpertCAD, check for all printers not just those that are local.
|
SRX00344
|
Thumb Tool & Engineering
|
Dual-dimensions (inch & metric, metric & inch) in
ExpertCAD does not work correctly for dimensions that include a tolerance.
|
SRX00325
|
AMT
|
When ExpertCAD prompts for tolerances for a dimension,
check the input to ensure that it can be converted to a real number.
|
SRX00326
|
AMT
|
The thumb wheel icon for switching between check
dimensions and theoretical dimensions is not working correctly in ExpertCAD
when the drawing standard is set to DIN.
|
SRX00328
|
AMT
|
Add the ability to import CL data files into ExpertCAD.
|
SRX00329
|
AMT
|
The tilt-wheel mouse event is not being handled by
ExpertCAM.
|
SRX00331
|
Philadelphia Mixing Solutions
|
Error in the computation of MOI of a tube. Hollow portion is not being handled properly.
|
SRX00351*
|
iFS Building Systems
|
The break-line icon is not functioning properly.
|
SRX00352*
|
Hiden Analytical
|
Can't define more than 64 standard notes.
|
SRX00353*
|
AMT
|
Incorrect error is output when setting a line style.
|
SRX00354*
|
gromaTec
|
WinPlot fails when more than 256 plotcap entries are defined.
|
SRX00355*
|
AMT
|
File/Plot/Current Class does not work if the class is a line style.
|
SRX00356*
|
AMT
|
WinPlot ignores line style 10 definitions.
|
SRX00357*
|
Bernal
|
The break-line icon is not functioning properly.
|
SRX00359*
|
Bernal
|
Text edit icon leaves the edited text current.
|
SRX00360*
|
Bernal
|
The puttext dialog has the previous text as a default instead of no default.
|
SRX00362*
|
AMT
|
Automatically update USB licenses to the latest version on install.
|
SRX00363*
|
Bernal
|
The command searchtext fails if searching for a null string.
|
SRX00364*
|
AMT
|
The file dialog for specifying a backup file is not working correctly.
|
SRX00365*
|
Bernal
|
Make the text buffer HOME read & write.
|
SRX00366*
|
AMT
|
Disabling automatic backup is not working correctly.
|
SRX00367*
|
AMT
|
Can’t read an ExpertCAD file > 4GB in size.
|
SRX00368*
|
Fontaine Engineering
|
Can't write an ExpertCAD drawing that will be > 4GB in size.
|
SRX00369*
|
Fontaine Engineering
|
Problems reading AutoCAD files containing block names with double byte character(s).
|
SRX00372*
|
AMT
|
Coordinates in the status bar are incorrect for very small zoom scales.
|
SRX00373*
|
Fontaine Engineering
|
Symbol for a locked entity is not being drawn to the screen.
|
SRX00374*
|
Bernal
|
Certain construction line icons do not draw the line after creating it.
|
SRX00375*
|
AMT
|
The ‘? r <file>’ ScriptLink command is failing for open and locked files.
|
SRX00376*
|
Fontaine GmbH
|
Problems reading AutoCAD files containing block names with double byte character(s).
|
SRX00377*
|
Hiden Analytica
|
Certain construction line icons do not draw the line after creating it.
|
SRX00378*
|
AMT
|
AutoCAD translator unnecessarily limits nesting of block references to 4 deep.
|
SRX00380*
|
AMT
|
Settings for Setup/Text Notes are not being saved correctly.
|
SRX00382*
|
AMT
|
Disable the Sent to Control menu item if there are no machining sequences defined in ExpertCAM.
|
SRX00383*
|
AMT
|
Post a confirmation dialog before overwriting a file when post processing in ExpertCAM.
|
SRX00385*
|
AMT
|
Custom color settings are not being honored by the AutoCAD translators.
|
SRX00386*
|
AMT
|
Insert / New Symbol feature is not working properly.
|